ACT20X-HUI-SAO-S

ZAR 0.00 ZAR 0.00
Out of stock
SKU
8965490000

Description:

  • Ex universal measuring isolating transformer and trip amplifier for RTD/TC temperature and DC current/voltage signals. This is a 1-channel measurement isolating transformer and trip amplifier with an external power supply that measures 22.5 mm in width. It is designed to capture and isolate signals from RTD/TC sensors, resistors, potentiometers, and DC current sources. Ex zones 0, 1, 2, and voltages 0...12 V and 0(4) ... 20 mA.
  • It is possible to supply sensors using the 0...20 mA current loop.
  • The output can be used as a passive 4...20 mA current loop or as an active 0(4) ...20 mA signal.
  • On the output side, there is a relay contact (NO) for monitoring limit values.
  • Relay contacts are used to send out error and status messages (NO).
  • The component can be set up with the help of common FDT and DTM software.
  • Extension housing for the TS35 rail installation
  • Dimensions: L/W/H 119.2/ 22.5/ 113.6
  • Screw connection/ Nominal cross-section 2.5 mm2
  • Protection degree: IP 20 
  • Input RTD: PT100, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Resistance 0...10 kΩ /
  • Potentiometer 10 Ohm... 10 kΩ, TC- Type: B, E, J, K, N, R, S, T, U, L, 0(4) ...20 mA, 0...12 V/ 2...10 V
  • Sensor supply 28...16.5 VDC / 0...20 mA                                   
  • Output active 0(4) ...20 mA / 20.0 mA configurable passive 4...20 mA current loop 3.5...26 V DC Load < 600 Ohm
  • Alarm output relay 1 NO contact 250 V AC / 30 V DC @ 2A safe zone, 32 V AC @ 0.5 A/ 32 VDC @ 1 A Zone 2
  • Accuracy < 0,1 % v.E
  • Temperature coefficient < 0,01% v.E./°C (Tu)
  • Alarm output relay 1 NO contact 250 V AC / 30 V DC @ 2A safe zone, 32 V AC @ 0.5 A/ 32 VDC @ 1 A Zone 2
  • Auxiliary power 19...31.2 V DC
  • Power loss approx. 3.5 W
  • Ambient
  • temperature range -20 °C... +60 °C
  • Secure isolation EN 61010, 3-way isolation up to 2.6 kV AC/DC of all circuits against each other
  • Working voltage 300 V AC/DC at overvoltage category II and pollution degree 2
  • Approvals cULus, ATEX IECEX, FM
  • ATEX marking II 3 G ExnA nC IIC T4
  • ATEX characteristic data U0 = 8.7 V DC, I0 = 18.4 mA DC, P0 = 40 mW
Back to Top