A2C 6 BL

ZAR 30.79
Out of stock
SKU
1991790000

A2C 6 BL:

  • In electrical engineering and panel building, the traditional prerequisite is to pass through power, signal, and data.
  • The insulating substance, connection system, and terminal block design are key distinguishing elements.
  • One or more conductors can be joined or connected using a feed-through terminal block.
  • They may have many connection levels with the same potential or are insulated from each other.

Dimensions and weights:

  • Depth: 45.5 mm.
  • Depth (inches): 1.791 inch.
  • Depth including DIN rail: 46 mm.
  • Height: 66.5 mm.
  • Height (inches): 2.618 inch.
  • Width: 8.1 mm.
  • Width (inches): 0.319 inch.
  • Net weight: 16.37 g.

Material data:

  • Material: Wemid.
  • Colour: Blue.
  • Colour of operational elements: orange.
  • UL 94 flammability rating: V-0.

Rating data IECEx/ATEX:

  • Certificate No. (ATEX): TUEV16ATEX7939U.
  • Certificate No. (IECEX): IECEXTUR16.0045U.
  • Max. voltage (ATEX): 550 V.
  • Current (ATEX): 37 A.
  • Wire cross section max. (ATEX): 6 mm².
  • Max. voltage (IECEX): 550 V.
  • Current (IECEX): 37 A.
  • Wire cross section max. (IECEX): 6 mm².
  • Marking EN 60079-7: Ex ec II C Gc.
  • Ex 2014/34/EU label: II 3 G D.

System specifications:

  • End cover plate required: Yes.
  • Number of potentials: 1.
  • Number of levels: 1.
  • Number of clamping points per level: 2.
  • Number of potentials per tier: 1.
  • Levels cross-connected internally: No.
  • PE connection: No.
  • Rail: TS 35.
  • N-function: No.
  • PE function: No.
  • PEN function: No.

Additional technical data:

  • Explosion-tested version: Yes.
  • Installation advice: Rail.
  • Open sides: right.
  • Snap-on: No.
  • Type of fixing: Snap-on.
  • Type of mounting: TS 35.
  • With snap-in pegs: No.

Conductors for clamping (additional connection):

  • Connection type, additional connection: PUSH IN.

Conductors for clamping (rated connection):

  • Blade size: 1.0 x 5.5 mm.
  • Clamping range, max.: 10 mm².
  • Clamping range, min.: 0.34 mm².
  • Connection cross-section, stranded, max.: 6 mm².
  • Connection cross-section, stranded, min.: 0.5 mm².
  • Connection direction: top.
  • Gauge to IEC 60947-1: A5.
  • Number of connections: 2.
  • Stripping length: 12 mm.
  • Tube length for twin wire-end ferrule:
    • Tube length:
      • min.: 10 mm.
      • nominal: 10 mm.
      • max.:12 mm.
    • Cross-section for conductor connection:
      • nominal:0.5 mm².
      • min.: 0.5 mm².
      • max.: 1 mm².
      Tube length:
    • min.: 10 mm.
    • max.: 18 mm
  • Cross-section for conductor connection:
    • nominal: 0.75 mm².
    • min.: 1.5 mm².
    • max.: 2.5 mm².
  • Tube length:
    • min.: 12 mm.
    • max.: 18 mm.
    • Cross-section for conductor connection:
      • nominal: 4 mm².
      • min.: 1 mm².
      • max.: 1.5 mm².
  • Tube length for wire-end ferrule with plastic collar DIN 46228/4:
    • Tube length:
      • min.: 10 mm.
      • nominal: 10 mm.
      • max.: 12 mm.
    • Cross-section for conductor connection:
      • nominal: 0.5 mm².
      • min.: 0.5 mm².
      • max.: 1 mm².
    • Tube length:
      • min.: 10 mm.
      • max.: 18 mm.
    • Cross-section for conductor connection:
      • nominal.: 0.75 mm².
      • min.: 1.5 mm².
      • max.: 2.5 mm².
    • Tube length:
      • min.: 12 mm.
      • max.: 18 mm.
    • Cross-section for conductor connection:
      • nominal.: 4 mm².
      • min.: 1 mm².
      • max.: 1.5 mm².
    • Tube length:
      • min.: 10 mm.
      • max.: 18 mm.
    • Cross-section for conductor connection:
      • min.: 6 mm².
      • max.: 10 mm².
  • Tube length for wire-end ferrule without plastic collar DIN 46228/1:
    • Tube length:
      • min.: 10 mm.
      • nominal: 10 mm.
      • max.: 12 mm.
    • Cross-section for conductor connection:
      • nominal: 0.5 mm².
      • min.: 0.5 mm².
      • max.: 1 mm².
    • Tube length:
      • min.: 10 mm.
      • max.: 18 mm.
    • Cross-section for conductor connection:
      • nominal: 0.75 mm².
      • min.: 1.5 mm².
      • max.: 2.5 mm².
    • Tube length:
      • min.: 12 mm.
      • max.: 18 mm.
    • Cross-section for conductor connection:
      • nominal: 4 mm².
      • min.: 1 mm².
      • max.: 1.5 mm².
    • Tube length:
      • min.: 10 mm.
      • max.: 18 mm.
    • Cross-section for conductor connection:
      • min.: 6 mm².
      • max.: 10 mm².
  • Twin wire-end ferrules, max.: 1.5 mm².
  • Twin wire-end ferrules, min.: 0.5 mm².
  • Type of connection: PUSH IN.
  • Wire connection cross section AWG, max.: AWG 8.
  • Wire connection cross section AWG, min.: AWG 22.
  • Wire connection cross section, finely stranded, max.: 10 mm².
  • Wire connection cross section, finely stranded, min.: 0.5 mm².
  • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.: 10 mm².
  • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.: 0.5 mm².
  • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 6 mm².
  • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.5 mm².
  • Wire connection cross-section, solid core, max.: 6 mm².
  • Wire connection cross-section, solid core, min.: 0.5 mm².

CSA rating data:

  • Certificate No. (CSA): 200039-70089609.
  • Current size B (CSA): 38 A.
  • Current size C (CSA): 38 A.
  • Current size D (CSA): 5 A.
  • Voltage size B (CSA): 600 V.
  • Voltage size C (CSA): 600 V.
  • Voltage size D (CSA): 600 V.
  • Wire cross section max. (CSA): 8 AWG.
  • Wire cross section min. (CSA): 22 AWG.

General:

  • Installation advice: Rail.
  • Rail: TS 35.
  • Standards: IEC 60947-7-1.
  • Wire connection cross section AWG, max.: AWG 8.
  • Wire connection cross section AWG, min.: AWG 22.

Rating data:

  • Rated cross-section: 6 mm².
  • Rated voltage: 800 V.
  • Rated DC voltage: 800 V.
  • Rated current: 41 A.
  • Current at maximum wires: 41 A.
  • Standards: IEC 60947-7-1.
  • Volume resistance according to IEC 60947-7-x: 0.78 mΩ.
  • Rated impulse withstand voltage: 8 kV.
  • Power loss in accordance with IEC 60947-7-x: 1.31 W.
  • Pollution severity: 3.
  • Surge voltage category: III.

UL rating data:

  • Certificate No. (cURus): E60693.
  • Conductor size Factory wiring max. (cURus): 8 AWG.
  • Conductor size Factory wiring min. (cURus): 22 AWG.
  • Conductor size Field wiring max. (cURus): 8 AWG.
  • Conductor size Field wiring min. (cURus): 22 AWG.
  • Current size B (cURus): 38 A.
  • Current size C (cURus): 38 A.
  • Current size D (cURus): 5 A.
  • Voltage size B (cURus): 600 V.
  • Voltage size C (cURus): 600 V.
  • Voltage size D (cURus): 600 V.