A3C 6 BL
A3C 6 BL:
- In electrical engineering and panel building, the traditional prerequisite is to pass through power, signal, and data.
- The insulating substance, connection system, and terminal block design are key distinguishing elements.
- One or more conductors can be joined or connected using a feed-through terminal block.
- They may have many connection levels with the same potential or are insulated from each other.
Dimensions and weights:
- Depth: 45.5 mm.
- Depth (inches): 1.791 inch.
- Depth including DIN rail: 46 mm.
- Height: 84.5 mm.
- Height (inches): 3.327 inch.
- Width: 8.1 mm.
- Width (inches): 0.319 inch.
- Net weight: 22.25 g.
Temperatures:
- Storage temperature: -25 °C - 55 °C.
- Continuous operating temp., min.: -60 °C.
- Continuous operating temp., max.: 130 °C.
Environmental Product Compliance:
- REACH SVHC: /.
Material data:
- Material: Wemid.
- Colour: Blue.
- Colour of operational elements: orange.
- UL 94 flammability rating: V-0.
Rating data IECEx/ATEX:
- Certificate No. (ATEX): TUEV16ATEX7939U.
- Certificate No. (IECEX): IECEXTUR16.0045U.
- Max. voltage (ATEX): 550 V.
- Current (ATEX): 36 A.
- Wire cross section max. (ATEX): 6 mm².
- Max. voltage (IECEX): 550 V.
- Current (IECEX): 36 A.
- Wire cross section max. (IECEX): 6 mm².
- Marking EN 60079-7: Ex ec II C Gc.
- Ex 2014/34/EU label: II 3 G D.
System specifications:
- End cover plate required: Yes.
- Number of potentials: 1.
- Number of levels: 1.
- Number of clamping points per level: 3.
- Number of potentials per tier: 1.
- Levels cross-connected internally: No.
- PE connection: No.
- Rail: TS 35.
- N-function: No.
- PE function: No.
- PEN function: No.
Additional technical data:
- Explosion-tested version: Yes.
- Installation advice: Rail.
- Open sides: right.
- Snap-on: No.
- Type of fixing: Snap-on.
- Type of mounting: TS 35.
- With snap-in pegs: No.
Conductors for clamping (additional connection):
- Connection type, additional connection: PUSH IN.
Conductors for clamping (rated connection):
- Blade size: 1.0 x 5.5 mm.
- Clamping range, max.: 10 mm².
- Clamping range, min.: 0.34 mm².
- Connection cross-section, stranded, max.: 6 mm².
- Connection cross-section, stranded, min.: 0.5 mm².
- Connection direction: top.
- Gauge to IEC 60947-1: A5.
- Number of connections: 3.
- Stripping length: 12 mm.
- Tube length for twin wire-end ferrule:
- Tube length:
- min.: 10 mm.
- nominal: 10 mm.
- max.:12 mm.
- Cross-section for conductor connection:
- nominal:0.5 mm².
- min.: 0.5 mm².
- max.: 1 mm².
- min.: 10 mm.
- max.: 18 mm
- Cross-section for conductor connection:
- nominal: 0.75 mm².
- min.: 1.5 mm².
- max.: 2.5 mm².
- Tube length:
- min.: 12 mm.
- max.: 18 mm.
- Cross-section for conductor connection:
- nominal: 4 mm².
- min.: 1 mm².
- max.: 1.5 mm².
- Tube length for wire-end ferrule with plastic collar DIN 46228/4:
- Tube length:
- min.: 10 mm.
- nominal: 10 mm.
- max.: 12 mm.
- Cross-section for conductor connection:
- nominal: 0.5 mm².
- min.: 0.5 mm².
- max.: 1 mm².
- Tube length:
- min.: 10 mm.
- max.: 18 mm.
- Cross-section for conductor connection:
- nominal.: 0.75 mm².
- min.: 1.5 mm².
- max.: 2.5 mm².
- Tube length:
- min.: 12 mm.
- max.: 18 mm.
- Cross-section for conductor connection:
- nominal.: 4 mm².
- min.: 1 mm².
- max.: 1.5 mm².
- Tube length:
- min.: 10 mm.
- max.: 18 mm.
- Cross-section for conductor connection:
- min.: 6 mm².
- max.: 10 mm².
- Tube length for wire-end ferrule without plastic collar DIN 46228/1:
- Tube length:
- min.: 10 mm.
- nominal: 10 mm.
- max.: 12 mm.
- Cross-section for conductor connection:
- nominal: 0.5 mm².
- min.: 0.5 mm².
- max.: 1 mm².
- Tube length:
- min.: 10 mm.
- max.: 18 mm.
- Cross-section for conductor connection:
- nominal: 0.75 mm².
- min.: 1.5 mm².
- max.: 2.5 mm².
- Tube length:
- min.: 12 mm.
- max.: 18 mm.
- Cross-section for conductor connection:
- nominal: 4 mm².
- min.: 1 mm².
- max.: 1.5 mm².
- Tube length:
- min.: 10 mm.
- max.: 18 mm.
- Cross-section for conductor connection:
- min.: 6 mm².
- max.: 10 mm².
- Twin wire-end ferrules, max.: 1.5 mm².
- Twin wire-end ferrules, min.: 0.5 mm².
- Type of connection: PUSH IN.
- Wire connection cross section AWG, max.: AWG 8.
- Wire connection cross section AWG, min.: AWG 22.
- Wire connection cross section, finely stranded, max.: 10 mm².
- Wire connection cross section, finely stranded, min.: 0.5 mm².
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.: 10 mm².
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.: 0.5 mm².
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 6 mm².
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.5 mm².
- Wire connection cross-section, solid core, max.: 6 mm².
- Wire connection cross-section, solid core, min.: 0.5 mm².
CSA rating data:
- Certificate No. (CSA): 200039-70089609.
- Current size B (CSA): 38 A.
- Current size C (CSA): 38 A.
- Current size D (CSA): 5 A.
- Voltage size B (CSA): 600 V.
- Voltage size C (CSA): 600 V.
- Voltage size D (CSA): 600 V.
- Wire cross section max. (CSA): 8 AWG.
- Wire cross section min. (CSA): 22 AWG.
General:
- Installation advice: Rail.
- Rail: TS 35.
- Standards: IEC 60947-7-1.
- Wire connection cross section AWG, max.: AWG 8.
- Wire connection cross section AWG, min.: AWG 22.
Rating data:
- Rated cross-section: 6 mm².
- Rated voltage: 800 V.
- Rated DC voltage: 800 V.
- Rated current: 41 A.
- Current at maximum wires: 41 A.
- Standards: IEC 60947-7-1.
- Volume resistance according to IEC 60947-7-x: 0.78 mΩ.
- Rated impulse withstand voltage: 8 kV.
- Power loss in accordance with IEC 60947-7-x: 1.31 W.
- Pollution severity: 3.
- Surge voltage category: III.
UL rating data:
- Certificate No. (cURus): E60693.
- Conductor size Factory wiring max. (cURus): 8 AWG.
- Conductor size Factory wiring min. (cURus): 22 AWG.
- Conductor size Field wiring max. (cURus): 8 AWG.
- Conductor size Field wiring min. (cURus): 22 AWG.
- Current size B (cURus): 38 A.
- Current size C (cURus): 38 A.
- Current size D (cURus): 5 A.
- Voltage size B (cURus): 600 V.
- Voltage size C (cURus): 600 V.
- Voltage size D (cURus): 600 V.
Brand | Weidmuller |
---|