AAP21 4 FS 100-250V

ZAR 287.43 ZAR 249.94
Out of stock
SKU
2460180000

AAP21 4 FS 100-250V:

  • The innovative modular concept can be customized to any type of machine.
  • The prospective distribution terminal blocks AAP are successful due to their consistent design, which has two construction options: alternating or clustered.
  • The control voltage distribution uses a grouped structure with potentials located on separate terminal blocks, forming whole potential blocks.

Dimensions and weights:

  • Depth: 82 mm.
  • Depth (inches): 3.228 inch.
  • Depth including DIN rail: 82.5 mm.
  • Height: 82 mm.
  • Height (inches): 3.228 inch.
  • Width: 6.1 mm.
  • Width (inches): 0.24 inch.
  • Net weight: 18.6 g.

Temperatures:

  • Storage temperature: -25 °C - 55 °C.
  • Continuous operating temp., min.: -60 °C.
  • Continuous operating temp., max.: 130 °C.

Environmental Product Compliance:

  • REACH SVHC: /.

Material data:

  • Material: Wemid.
  • Colour: dark beige.
  • Colour of operational elements: red.
  • UL 94 flammability rating: V-0.

Rating data IECEx/ATEX:

  • Certificate No. (ATEX): TUEV17ATEX8064U.
  • Certificate No. (IECEX): IECEXTUR17.0030U.
  • Current (ATEX): 6.3 A.
  • Wire cross section max. (ATEX): 4 mm².
  • Current (IECEX): 6.3 A.
  • Wire cross section max. (IECEX): 4 mm².
  • Marking EN 60079-7: Ex ec II C Gc.
  • Ex 2014/34/EU label: II 2 G D.

System specifications:

  • Version: With LED.
  • End cover plate required: Yes.
  • Number of potentials: 1.
  • Number of levels: 1.
  • Levels cross-connected internally: No.
  • Rail: TS 35.
  • Additional technical data:

    • Explosion-tested version: Yes.
    • Installation advice: Rail.
    • Open sides: right.
    • Snap-on: No.
    • Type of fixing: Snap-on.
    • Type of mounting: TS 35.
    • With snap-in pegs: No.

    Conductors for clamping (additional connection):

    • Connection type, additional connection: PUSH IN.

    Conductors for clamping (rated connection):

    • Blade size: 0.6 x 3.5 mm.
    • Clamping range, max.: 4 mm².
    • Clamping range, min.: 0.14 mm².
    • Connection cross-section, stranded, max.: 4 mm².
    • Connection cross-section, stranded, min.: 0.5 mm².
    • Connection direction: top.
    • Gauge to IEC 60947-1: A4.
    • Number of connections: 1.
    • Stripping length: 12 mm.
    • Tube length for twin wire-end ferrule:
      • Tube length:
        • min.: 8 mm.
        • max.: 12 mm.
      • Cross-section for conductor connection:
        • min.: 0.5 mm².
        • max.: 1.5 mm².
    • Tube length for wire-end ferrule with plastic collar DIN 46228/4:
      • Tube length:
        • min.: 8 mm.
        • max.: 12 mm.
      • Cross-section for conductor connection:
        • min.: 0.5 mm².
        • max.: 1.5 mm².
      • Tube length:
        • min.: 7 mm.
        • max.: 12 mm.
      • Cross-section for conductor connection:
        • min.: 1.5 mm².
        • max.: 2.5 mm².
      • Tube length:
        • min.: 9 mm.
        • max.: 15 mm.
      • Cross-section for conductor connection:
        • nominal: 4 mm².
    • Tube length for wire-end ferrule without plastic collar DIN 46228/1:
      • Tube length:
        • min.: 8 mm.
        • max.: 12 mm.
      • Cross-section for conductor connection:
        • min.: 0.5 mm².
        • max.: 1.5 mm².
      • Tube length:
        • min.: 7 mm.
        • max.: 12 mm.
      • Cross-section for conductor connection:
        • min.: 1.5 mm².
        • max.: 2.5 mm².
      • Tube length:
        • min.: 9 mm.
        • max.: 15 mm.
      • Cross-section for conductor connection:
        • nominal: 4 mm².
    • Twin wire-end ferrules, max.: 1.5 mm².
    • Twin wire-end ferrules, min.: 0.5 mm².
    • Type of connection: PUSH IN.
    • Wire connection cross section AWG, max.: AWG 12.
    • Wire connection cross section AWG, min.: AWG 26.
    • Wire connection cross section, finely stranded, max.: 4 mm².
    • Wire connection cross section, finely stranded, min.: 0.5 mm².
    • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.: 4 mm².
    • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.: 0.5 mm².
    • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 4 mm².
    • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.5 mm².
    • Wire connection cross-section, solid core, max.: 4 mm².
    • Wire connection cross-section, solid core, min.: 0.5 mm².

    CSA rating data:

    • Certificate No. (CSA): 200039-70089609.
    • Current size B (CSA): 10 A.
    • Current size C (CSA): 10 A.
    • Current size D (CSA): 10 A.
    • Voltage size B (CSA): 300 V.
    • Voltage size C (CSA): 150 V.
    • Voltage size D (CSA): 300 V.
    • Wire cross section max. (CSA): 10 AWG.
    • Wire cross section min. (CSA): 26 AWG.

    General:

    • Installation advice: Rail.
    • Rail: TS 35.
    • Standards: In accordance with IEC 60947-7-3.
    • Wire connection cross section AWG, max.: AWG 12.
    • Wire connection cross section AWG, min.: AWG 26.

    Rating data:

    • Rated cross-section: 4 mm².
    • Rated voltage: 250 V.
    • Rated voltage to adjoining terminal: 500 V.
    • Rated DC voltage: 250 V.
    • Rated current: 6.3 A.
    • Current at maximum wires: 6.3 A.
    • Standards: In accordance with IEC 60947-7-3.
    • Volume resistance according to IEC 60947-7-x: 1 mΩ.
    • Rated impulse withstand voltage: 4 kV.
    • Power loss in accordance with IEC 60947-7-x: 1.02 W.
    • Pollution severity: 2.
    • Surge voltage category: III.

    UL rating data:

    • Certificate No. (cURus): E60693.
    • Conductor size Factory wiring max. (cURus): 10 AWG.
    • Conductor size Factory wiring min. (cURus): 26 AWG.
    • Conductor size Field wiring max. (cURus): 10 AWG.
    • Conductor size Field wiring min. (cURus): 26 AWG.
    • Current size B (cURus): 10 A.
    • Current size C (cURus): 10 A.
    • Current size D (cURus): 10 A.
    • Voltage size B (cURus): 300 V.
    • Voltage size C (cURus): 150 V.
    • Voltage size D (cURus): 300 V.

    Important note:

    • Product information: The voltage depends on the selected fuse element or the selected indicator light.
More Information
SKU 2460180000
Brand Weidmuller
Write Your Own Review
You're reviewing:AAP21 4 FS 100-250V
Write your content here...
Back to Top