AAP21 4 FS

ZAR 156.86 ZAR 136.40
Out of stock
SKU
2428950000

AAP21 4 FS:

  • The innovative modular concept can be customized to any type of machine.
  • The prospective distribution terminal blocks AAP are successful due to their consistent design, which has two construction options: alternating or clustered.
  • The control voltage distribution uses a grouped structure with potentials located on separate terminal blocks, forming whole potential blocks.

Dimensions and weights:

  • Depth: 82 mm.
  • Depth (inches): 3.228 inch.
  • Depth including DIN rail: 82.5 mm.
  • Height: 82 mm.
  • Height (inches): 3.228 inch.
  • Width: 6.1 mm.
  • Width (inches): 0.24 inch.
  • Net weight: 18.4 g.

Temperatures:

  • Storage temperature: -25 °C - 55 °C.
  • Continuous operating temp., min.: -60 °C.
  • Continuous operating temp., max.: 130 °C.

Environmental Product Compliance:

  • REACH SVHC: /.

Material data:

  • Material: Wemid.
  • Colour: dark beige.
  • Colour of operational elements: red.
  • UL 94 flammability rating: V-0.

Rating data IECEx/ATEX:

  • Certificate No. (ATEX): TUEV17ATEX8064U.
  • Certificate No. (IECEX): IECEXTUR17.0030U.
  • Max. voltage (ATEX): 250 V.
  • Current (ATEX): 6.3 A.
  • Wire cross section max. (ATEX): 4 mm².
  • Max. voltage (IECEX): 250 V.
  • Current (IECEX): 6.3 A.
  • Wire cross section max. (IECEX): 4 mm².
  • Marking EN 60079-7: Ex ec II C Gc.
  • Ex 2014/34/EU label: II 2 G D.

System specifications:

  • Version: Without LED.
  • End cover plate required: Yes.
  • Number of potentials: 1.
  • Number of levels: 1.
  • Number of clamping points per level: 1.
  • Number of potentials per tier: 1.
  • Levels cross-connected internally: No.
  • PE connection: No.
  • Rail: TS 35.
  • N-function: No.
  • PE function: No.
  • PEN function: No.

Additional technical data:

  • Explosion-tested version: Yes.
  • Installation advice: Rail.
  • Open sides: right.
  • Snap-on: No.
  • Type of fixing: Snap-on.
  • Type of mounting: TS 35.
  • With snap-in pegs: No.

Conductors for clamping (additional connection):

  • Connection type, additional connection: PUSH IN.

Conductors for clamping (rated connection):

  • Blade size: 0.6 x 3.5 mm.
  • Clamping range, max.: 4 mm².
  • Clamping range, min.: 0.14 mm².
  • Connection cross-section, stranded, max.: 4 mm².
  • Connection cross-section, stranded, min.: 0.5 mm².
  • Connection direction: top.
  • Gauge to IEC 60947-1: A4.
  • Number of connections: 1.
  • Stripping length: 12 mm.
  • Tube length for twin wire-end ferrule:
    • Tube length:
      • min.: 6 mm.
      • max.: 10 mm.
    • Cross-section for conductor connection:
      • min.: 0.5 mm².
      • max.: 1 mm².
  • Tube length for wire-end ferrule with plastic collar DIN 46228/4:
    • Tube length:
      • min.: 6 mm.
      • max.: 10 mm.
    • Cross-section for conductor connection:
      • min.: 0.5 mm².
      • max.: 1 mm².
    • Tube length:
      • min.: 7 mm.
      • max.: 12 mm.
    • Cross-section for conductor connection:
      • min.: 1.5 mm².
      • max.: 2.5 mm².
    • Tube length:
      • min.: 9 mm.
      • max.: 15 mm.
    • Cross-section for conductor connection:
      • nominal: 4 mm².
  • Tube length for wire-end ferrule without plastic collar DIN 46228/1:
    • Tube length:
      • min.: 6 mm.
      • max.: 10 mm.
    • Cross-section for conductor connection:
      • min.: 0.5 mm².
      • max.: 1 mm².
    • Tube length:
      • min.: 7 mm.
      • max.: 12 mm.
    • Cross-section for conductor connection:
      • min.: 1.5 mm².
      • max.: 2.5 mm².
    • Tube length:
      • min.: 9 mm.
      • max.: 15 mm.
    • Cross-section for conductor connection:
      • nominal: 4 mm².
  • Twin wire-end ferrules, max.: 1.5 mm².
  • Twin wire-end ferrules, min.: 0.5 mm².
  • Type of connection: PUSH IN.
  • Wire connection cross section AWG, max.: AWG 12.
  • Wire connection cross section AWG, min.: AWG 26.
  • Wire connection cross section, finely stranded, max.: 4 mm².
  • Wire connection cross section, finely stranded, min.: 0.5 mm².
  • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.: 4 mm².
  • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.: 0.5 mm².
  • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 4 mm².
  • Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.5 mm².
  • Wire connection cross-section, solid core, max.: 4 mm².
  • Wire connection cross-section, solid core, min.: 0.5 mm².

General:

  • Installation advice: Rail.
  • Rail: TS 35.
  • Standards: In accordance with IEC 60947-7-3.
  • Wire connection cross section AWG, max.: AWG 12.
  • Wire connection cross section AWG, min.: AWG 26.

Rating data:

  • Rated cross-section: 4 mm².
  • Rated voltage: 500 V.
  • Rated voltage to adjoining terminal: 500 V.
  • Rated DC voltage: 500 V.
  • Rated current: 6.3 A.
  • Current at maximum wires: 6.3 A.
  • Standards: In accordance with IEC 60947-7-3.
  • Volume resistance according to IEC 60947-7-x: 1 mΩ.
  • Rated impulse withstand voltage: 4 kV.
  • Power loss in accordance with IEC 60947-7-x: 1.02 W.
  • Pollution severity: 3.
  • Surge voltage category: III.

UL rating data:

  • Certificate No. (cURus): E60693.
  • Conductor size Factory wiring max. (cURus): 10 AWG.
  • Conductor size Factory wiring min. (cURus): 26 AWG.
  • Conductor size Field wiring max. (cURus): 10 AWG.
  • Conductor size Field wiring min. (cURus): 26 AWG.
  • Current size B (cURus): 10 A.
  • Current size C (cURus): 10 A.
  • Current size D (cURus): 10 A.
  • Voltage size B (cURus): 300 V.
  • Voltage size C (cURus): 150 V.
  • Voltage size D (cURus): 300 V.

Important note:

  • Product information: The voltage depends on the selected fuse element or the selected indicator light.
More Information
SKU 2428950000
Brand Weidmuller
Write Your Own Review
You're reviewing:AAP21 4 FS
Write your content here...
Back to Top