Back to Top
DC motors LAK2080C
Basic design features:
- The stator, main poles, and interpoles are all completely laminated.
- The low induced voltage is due to the armature's well-proportioned length-to-diameter ratio.
- Low bar-to-bar voltage ensures proper commutation.
- Large thermal masses (copper and steel weights) result in a high thermal time constant.
- Well-designed end frames and louvres allow for easy examination while also reducing noise.
- NDE spigots and stub shafts are standard, accepting adaptors for all well-known tachometer and pulse generator brands.
- High efficiency is achieved through low field losses and a well-proportioned air gap between the armature and stator.
- Brush and commutator wear is minimal because of effective commutation.
- A 1-phase thyristor supply without external inductance saves money and space.
- Excellent short-time overload characteristics allow for the use of a smaller motor in many circumstances.
- High-armature voltages are standard.
- High mechanical and electrical flexibility.
- paint with exceptional resistance to corrosion.
- Conforms to IEC, BS, and VDE standards.
- Available, according to NEMA.
- Available CSA-approved.
Specifications Standards:
- IEC 34–IIEC 72.
- VDE 0530, BS 4999.
Insulation:
- Class F.
Balance:
- IEC 34-14 grade 'N'.
- Grade 'R' on request.
Temperature rise:
- Class F, 1050 C by resistance.
Overload capacity:
- 1.6 x FLT for 15 seconds every 5 minutes.
- 2.0 x nom. armature current for 30 seconds every 15 minutes.
Terminal box position:
- Standard: top mounting.
- Side-mounting is available on request.
Blower position:
- LAK 2080 and 2100: On either side of the motor.
- LAK 2112 and 2132: On top or either side of the motor.
Bearings:
- Sealed-for-life preloaded ball bearings.
Armature voltages:
- Available up to: LAK 2080-2100: 470 V.
Mechanical data:
- Inertia J - kgm²: 0.0038.
- Max. mechanical speed (min-1): 6500.
Cooling data:
- IC06/17/37.
- Air volume m3/h: 30.
- Pressure drop in motor n/m2: 100.
- IC416.
- Air volume m3/h: 45.
- Pressure drop n/m2: 85.
Blower motor data:
- IC06.
- Blower type: I.
- Electric supply: 1 x 220 - 240V 50 Hz.
- F.L.C (A): 0.18.
Bearing data:
- Max. axial force F in Newton Ball bearings:
- 630 min-1: 520.
- 800 min-1: 470.
- 1000 min-1: 435.
- 1250 min-1: 390.
- 1600 min-1: 360.
- 2000 min-1: 335.
- 2500 min-1: 300.
- 3200 min-1: 270.
Brand | T-T Electric |
---|
Write Your Own Review
Write your content here...