DC Tachogenerators, Bearing less configuration, GTB9.16L/460

ZAR 0.00
Out of stock
SKU
GTB9.16L/460

Blind hollow shaft ø12...16 mm, Housing ø95 mm:

  • Response time is low.
  • Open-circuit voltage ranges from 10 to 60 mV per rpm.
  • Blind hollow shaft ø12–16 mm or cone shaft ø17 mm (1:10).
  • Patented Long-Life technology ensures high signal quality.
  • IP 68, high protection.
  • Connector output.
  • No further energy source is needed.

Technical data:

  • Off-load voltage U0 [mV/rpm]: 60.
  • Minimum load required depending on speed range [rpm]:
    • 0-1000 RL [kΩ]: >60.
    • 0-3000 RL [kΩ]: >144.
  • Maximum operating speed nmax [rpm]: 6000.
  • Armature resistance RA (20°C) [Ω]: 340.
  • Armature inductance LA [mH]: 275.
More Information
Brand Baumer Thalheim
Write Your Own Review
You're reviewing:DC Tachogenerators, Bearing less configuration, GTB9.16L/460
Write your content here...