Back to Top
PRO TOP1 240W 24V 10A EX
PRO TOP1 240W 24V 10A EX:
- Production procedures must always be optimized for efficiency.
- In addition to performance, energy efficiency and sustainability are becoming increasingly crucial in cutting-edge industries.
- PROtop power supplies combine great performance statistics with exemplary sustainability, increasing overall manufacturing facility productivity.
- PROtop provides a number of benefits that give you a distinct competitive advantage.
- High efficiency lead to lower energy costs and increased plant availability through longer service life and MTBF values.
- Furthermore, there is a high functional density due to the exceptionally space-efficient designs.
- PROtop can save significantly more than conventional power supply devices.
- Its higher efficiency saves an average of 50 kWh per day in a medium-sized production facility with around 100 PROtop power supply operating on three shifts.
- This adds up to over 15,000 kWh each year while also lowering the facility's carbon footprint.
- The service life, which is twice as long as that of typical power supply, also minimizes repurchase and exchange expenses over time.
Dimensions and weights:
- Depth: 125 mm.
- Depth (inches): 4.921 inch.
- Height: 130 mm.
- Height (inches): 5.118 inch.
- Width: 39 mm.
- Width (inches): 1.535 inch.
- Net weight: 956 g.
Temperatures:
- Storage temperature: -40 °C - 85 °C.
- Operating temperature: -40 °C - 70 °C.
- Humidity at operating temperature: 5 - 100 % no condensation.
Environmental Product Compliance:
- REACH SVHC: Lead 7439-92-1.
- SCIP: 6d8cdf22-8230-4af8-86c8-3558c716666d.
Input:
- AC input voltage range: 85 - 277 V AC.
- Connection system: Clamping yoke.
- Current consumption in relation to the input voltage:
- Voltage type: AC.
- Input voltage: 100 V.
- Input current: 4 A.
- Voltage type: DC.
- Input voltage: 120 V.
- Input current: 4 A.
- DC input voltage range: 80 - 410 V DC.
- Frequency range AC: 45 - 65 Hz.
- Input fuse (internal): Yes.
- Inrush current: max. 5 A.
- Nominal power consumption: 260.9 VA.
- Rated input voltage: 110 - 240 V AC / 120 - 340 V DC.
- Recommended back-up fuse: 5 A, DI / 6 A, Char. B / 6 A, Char C.
- Surge protection: Varistor.
Output:
- Connection system: Clamping yoke connection.
- DCL - peak load reserve:
- Boost duration: 5 s.
- Multiple of the rated current: 150 %.
- Boost duration: 15 ms.
- Multiple of the rated current: 600 %.
- Mains failure bridge-over time: > 20 ms @ 115V AC/ 230 VAC.
- Nominal output current for Unom: 10 A @ 60 °C.
- Output power: 240 W.
- Output voltage, max.: 28.8 V.
- Output voltage, min.: 22.5 V.
- Output voltage, note: adjustable with potentiometer or communication module.
- Parallel connection option: yes, max 10.
- Protection against inverse voltage: Yes.
- Ramp-up time: ≤ 100 ms.
- Rated output voltage: 24 V DC ± 1 %.
- Residual ripple, breaking spikes: <50 mVss @ UNenn, Full Load.
General data:
- AC failure bridging time @ Inom: > 20 ms @ 230 V AC / > 20 ms @ 115 V AC.
- Conformal coating: Yes.
- Degree of efficiency: 92%.
- Derating: > 60°C (2.5% / 1°C).
- Earth leakage current, max.: 3.5 mA.
- Housing version: Metal, corrosion resistant.
- MTBF:
- According to Standard: SN 29500.
- Operating time (hours), min.: 1,600,000 h.
- Ambient temperature: 25 °C.
- Input voltage: 230 V.
- Output power: 240 W.
- Duty cycle: 100 %.
- According to Standard: SN 29500.
- Operating time (hours), min.: 763,000 h.
- Ambient temperature: 40 °C.
- Input voltage: 230 V.
- Output power: 240 W.
- Duty cycle: 100 %.
- Power factor (approx.): > 0.9.
- Power loss, idling: 5 W.
- Power loss, nominal load: 20.8 W.
- Protection degree: IP20.
- Short-circuit protection: Yes, internal.
- Start-up: ≥ -40 °C.
- Surge voltage category: III, II.
EMC / shock / vibration:
- Interference immunity test acc. to: EN 55032:2015, EN 55024:2010/A1:2015, EN 55035:2017, EN 61000-3-2:2014, EN 61000-6-1:2007, EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011, EN 61000-6-4:2007/A1:2011.
- Noise emission in accordance with EN55032: Class B.
- Shock resistance IEC 60068-2-27: 30 g in all directions.
- Vibration resistance IEC 60068-2-6: 2.3 g (on DIN rail), 4 g (with direct mounting).
Insulation coordination:
- Insulation voltage input / earth: 3.2 kV.
- Insulation voltage output / earth: 0.5 kV.
- Insulation voltage, input/output: 3.5 kV.
- Pollution severity: 2.
- Protection class: I, with PE connection.
- Surge voltage category: III, II.
Electrical safety (applied standards):
- Electrical machine equipment: Acc. to EN60204.
- For use with electronic equipment: Acc. to EN50178 / VDE0160.
- Protection against dangerous shock currents: Acc. to VDE0106-101.
- Protective separation / protection against electrical shock: VDE0100-410 / acc. to DIN57100-410.
- Safety extra-low voltage: SELV acc. to IEC 60950-1, PELV according to EN 60204-1.
- Safety transformers for switch-mode power supplies: According to EN 61558-2-16.
Connection data (input):
- Conductor cross-section, AWG/kcmil, max.: 12 AWG.
- Conductor cross-section, AWG/kcmil, min.: 30 AWG.
- Conductor cross-section, flexible, min.: 0.2 mm².
- Conductor cross-section, rigid, max.: 4 mm².
- Conductor cross-section, rigid, min.: 0.2 mm².
- Connection system: Clamping yoke.
- Number of terminals: 3 for L/N/PE.
- Screwdriver blade: 0.6 x 3.5.
- Wire connection cross section, flexible (input), max.: 4 mm².
Connection data (output):
- Conductor cross-section, AWG/kcmil, max.: 12 AWG.
- Conductor cross-section, AWG/kcmil, min.: 30 AWG.
- Conductor cross-section, flexible, max.: 4 mm².
- Conductor cross-section, flexible, min.: 0.2 mm².
- Conductor cross-section, rigid, max.: 4 mm².
- Conductor cross-section, rigid, min.: 0.2 mm².
- Connection system: Clamping yoke connection.
- Number of terminals: 5 (+ + / - - -).
- Screwdriver blade: 0.6 x 3.5.
Connection data (signal):
- Wire connection cross-section, flexible (signal), max.: 1.5 mm².
- Wire connection cross-section, flexible (signal), min.: 0.2 mm².
- Wire connection method: Screw connection.
- Wire cross-section, AWG/kcmil, max.: 16.
- Wire cross-section, AWG/kcmil, min.: 28 mm².
- Wire cross-section, solid, max.: 1.5 mm².
- Wire cross-section, solid, min.: 0.2 mm².
Signalling:
- Floating contact: Yes.
- LED green/red:
- Green: Operation (failure-free).
- Flashing green: advance warning I>90%.
- Green/red flashing: output switched off (switch-off mode).
- Flashing red: overload/error.
- Status relay (max. load): Output voltage OK (30 V DC / 1 A).
Approbations:
- Certificate no. (cULus): E258476.
- Certificate no. (cULusEX): E470829.
- Institute (cULus): CULUS.
- Institute (cULusEX): CULUSEX.
Brand | Weidmuller |
---|
Write Your Own Review
Write your content here...