touchMATRIX® IO-Link Indicator AX350-IO Options

ZAR 0.00
Out of stock
SKU
AX350-IO-Options

Process indicators for IO-Link:

  • The Motrona touchMATRIX® display series offers a variety of possibilities.
  • The new IO option provides a connection to the IO-Link world.
  • Process indicators with IO-Link are Industry 4.0 compatible.
  • It allows the digitalization of conventional analogue sensors.
  • This results in a variety of innovative features for standard sensors, such as the ability to transmit status information, configure devices while they are in use, or scale and evaluate analogue sensors digitally.

IO-Link Indicator:

  • There are multiple options available for the AX350 IO-Link V1.1.

Option IO (= IO-Link Device):

  • Transferring data using COM3 (230,4 k Baud).
  • 3 msec for cycle times.

Process data IN 32 bytes (6 x process values from AX350):

  • Analog value 1 (scaled or linearized) and unit.
  • Analog value 2 (scaled or linearized) and unit.
  • Analog value 1 (scaled / linearized) with totalization and unit.
  • Analog value 2 (scaled or linearized) with totalization and unit.
  • Combine analogue value 1 (scaled/linearized) with analogue value 2 (scaled/linearized) and unit.
  • Combine totalisator analogue value 1 (scaled/linearized) with totalisator analogue value 2 (scaled/linearized) and unit.

Process data out 8 bytes (2 x IO-Link process values to AX350):

  • IOL process value Out 1 with scaling, decimal point adjustment, and programmable units.
  • IOL process values Out 2 with scaling, decimal point adjustment, and programmable units.

Additional choices (which can be combined):

Option AC (=Alternating Current):

  • Power supply: 50–60 Hz, 115–230 VAC.

Option AO (= All Outputs/RS232):

4 control outputs:

  • Format / level: 5–30 VDC (external voltage COM+), PNP.
  • Maximum output current: 200 mA.
  • Reaction time: < 1 ms.

Analog output:

  • Output voltage: ±10 V (max. 2 mA), or output current: 0/4–20 mA (max. 270 Ohm).
  • Resolution: 16 bits (scalable), ±15 bits.
  • Accuracy: ±0.1%.

Serial interface (RS232):

  • Asynchronous data transmission.
  • Baud rate: 9600, 19200, or 38400 Baud.
  • Lecom protocol.

Option AR (= All outputs/RS485):

4 control outputs:

  • Format/level: 5–30 VDC (external voltage COM+), PNP.
  • Maximum output current: 200 mA.
  • Reaction time: < 1 ms.

Analog output:

  • Output voltage: ±10 V (max. 2 mA), or output current: 0/4–20 mA (max. 270 Ohm).
  • Resolution: 16 bits (scalable), resp. ±15 bits.
  • Accuracy: ±0.1%.

Serial Interface (RS485):

  • Asynchronous data transmission.
  • Baud rate: 19200, 38400, or 9600 Baud.
  • Lecom protocol.

Option CO (= control outputs/RS232):

4 control outputs:

  • Format/level: 5–30 VDC (external voltage COM+), PNP.
  • Maximum output current: 200 mA.
  • Reaction time: < 1 ms.

Serial Interface (RS232):

  • Asynchronous data transmission.
  • Baud rate: 9600, 19200, or 38400 Baud.
  • Lecom protocol.

Option CR (=Control Outputs/RS485):

4 control outputs:

  • Format/level: 5–30 VDC (external voltage COM+), PNP.
  • Maximum output current: 200 mA.
  • Reaction time: < 1 ms.

Serial Interface (RS485):

  • Asynchronous data transmission.
  • Baud rate: 9600, 19200, or 38400 Baud.
  • Lecom protocol.

Option RL (=Relays):

2 output relays with a potential-free changeover:

  • Switching capacity (AC): maximum 250 VAC / 3 A / 750 VA.
  • Maximum switching capacity (DC): 150 VDC / 2 A / 50 W.
  • Reaction time: <20 ms.