Back to Top
TouchMATRIX® IO-Link Indicator AX350-IO
Pricing available on request
Description:
- The touchMATRIX® series' display devices come with a 186 × 64-pixel graphic display by default.
- As a result, there are several ways to display plaintext, symbols, and units. The red, green, and yellow visual representation is made possible by the LED backlight display.
- These colour modifications can be employed event-dependently (e.g. in case of limit values) because of the intuitive parameterization.
- The modular, arbitrarily combinable configuration with analog output, switching outputs, relay, serial interface (Modbus), and 115... 230 VAC demonstrates the highest level of connection and application versatility.
- The touchMATRIX® displays are perfect for use in the food industry because of its IP65 and resistive touch panel.
Specifications:
- 2 universal 16 bit analog inputs for ±10 V or 0/4 … 20 mA.
- 3 control inputs for HTL / PNP signals.
- Power supply 18 ... 30 VDC.
- 24 V auxiliary output for encoder supply.
- High accuracy reference output 10 V for potentiometers > 1 kOhm.
- 3.78 x 1.89-inch norm panel housing and IP65 protection.
- Bright and high-contrast display with event-dependent colour variations.
- Emulation of a 7-segment display inclusively icons and units.
- Intuitive and easy parameterization by plain text and touchscreen.
- Operating modes for visualization of INPUT 1, INPUT 2 or combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2.
- Numerous features, e. g. Ttara, filters, averaging.
- Linearization with 24 control points.
Option IO (= IO-Link Device):
- Data transfer via COM3 (230,4 kBaud).
- Cycle times < 3 msec.
- Process data IN 32 Byte (6 x process values from AX350):
- Analog value 1 (scaled / linearized) and unit.
- Analog value 2 (scaled / linearized) and unit.
- Analog value 1 (scaled / linearized) with totalisation and unit.
- Analog value 2 (scaled / linearized) with totalisation and unit.
- Shortcut analog value 1 (scaled / linearized) with analog value 2 (scaled / linearized) and unit.
- Shortcut totalisator analog value 1 (scaled / linearized) with totalisator analog value 2 (scaled / linearized) and unit.
- Process data Out 8 Byte (2 x IO-Link process values to AX350):
- IOL process value Out 1 with scaling, adjustable decimal point and programmable units.
- IOL process values Out 2 with scaling, adjustable decimal point and programmable units.
Brand | Motrona |
---|