UR20-1COM-232-485-422

ZAR 7,171.52
Out of stock
SKU
1315750000

Remote I/O module, IP20, 1-channel, communication protocols RS232/RS485/RS422, PUSH IN connection:

  • In today's automated systems, incremental and absolute value encoders are essential components.
  • Weidmüller provides you with a variety of counter modules that can take input frequencies up to 500 kHz. These counter modules were created specifically for these applications.
  • The synchronous serial interface (SSI) module allows high precision positioning tasks to be realized with absolute value encoders.
  • To accommodate all applications, the module can be parameterized for listening or master mode operation.
  • A pulse input module is available for frequency measurement up to 100 kHz, while the UR20-1CNT-500 has an input that can handle frequencies up to 500 kHz.
  • The UR20-2CNT-100 module has two independent counter inputs; it is supplemented with the UR20-1CNT-100-1DO module, which has one counter but provides additional options via a latch, gate, and reset input.
  • THIS PERMITS EXTERNAL COUNTER CONTROL.
  • In addition, this module can trigger an immediate event via a digital output using a predefined reference value.
  • The UR20-1COM-232-485-422 MODULE GIVES YOU EXTENDED OPTIONS FOR COMMUNICATION; DEVICES CAN BE CONSISTENTLY INTEGRATED IN U-REMOTE SYSTEMS VIA AN RS232, RS485 OR RS422 INTERFACE, FOR EXAMPLE.
  • The UR20-1COM-SAI PRO MODULE PROVIDES A SOLUTION FOR CONNECTING THE CONTROL CABINET TO THE FIELD.
  • UP TO 15 DECENTRAL IP67 SAI-PRO SUBBUS MODULES PER U-REMOTE MODULE CAN BE INTEGRATED USING THIS GATEWAY.
  • THE MODULE ELECTRONICS SUPPLY CONNECTED SENSORS With POWER TO THE INPUT current path (UIN)

Specifications dimensions and weights:

  • Depth: 76 mm.
  • Depth (inches): 2.992 inch.
  • Height: 120 mm.
  • Height (inches): 4.724 inch.
  • Width: 11.5 mm.
  • Width (inches): 0.453 inch.
  • Mounting dimension - height: 128 mm.
  • Net weight: 87.03 g.

Temperatures:

  • Storage temperature: -40 °C - +85 °C.
  • Operating temperature: -20 °C - +60 °C.

Environmental Product Compliance:

  • REACH SVHC: Lead 7439-92-1.
  • SCIP: 82327f13-cd27-455a-ab5b-a62e1996dcf8.

Connection data:

  • Type of connection: PUSH IN.
  • Wire connection cross section, finely stranded, maximum: 1.5 mm².
  • Wire connection cross section, finely stranded, minimum: 0.14 mm².
  • Wire cross-section, finely stranded, maximum (AWG): AWG 16.
  • Wire cross-section, finely stranded, minimum (AWG): AWG 26.
  • Wire cross-section, solid, maximum: 1.5 mm².
  • Wire cross-section, solid, maximum (AWG): AWG 16.
  • Wire cross-section, solid, minimum: 0.14 mm².
  • Wire cross-section, solid, minimum (AWG): AWG 26.

General data:

  • Air humidity (operation): 10% to 95%, non-condensing as per DIN EN 61131-2.
  • Air humidity (storage): 10% to 95%, non-condensing as per DIN EN 61131-2.
  • Air humidity (transport): 10% to 95%, non-condensing as per DIN EN 61131-2.
  • Air pressure (operation): ≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2.
  • Air pressure (storage): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2.
  • Air pressure (transport): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2.
  • Pollution severity: 2.
  • Rail: TS 35.
  • Shock: 15 g over 11 ms, half sinus wave, acc.to IEC 60068-2-27.
  • Surge voltage category: II.
  • Test voltage: 500 V.
  • UL 94 flammability rating: V-0.
  • Vibration resistance: 5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6.

IP67 interface:

  • Output current, supply voltage: maximum 500 mA.

Power supply:

  • Current consumption from IIN (the respective power segment): 16 mA + load.
  • Current consumption from Isys, typ.: 8 mA.
  • Voltage supply: 24 V DC +20 %/ -15 % via the system bus.

RS interface:

  • Output current, supply voltage: maximum 500 mA.
  • Standards RS232: DIN 66020, DIN 66259, EIA-RS 232C, CCITT V.24/V.28.
  • Standards RS485/422: DIN 66259 Part 1 und 3, EIA-RS 422/485, CCITT V.11.

System data:

  • Field bus protocol: PROFINET IRT, PROFINET RT, CC-Link IE TSN, IEC 61162-450, PROFIBUS DP-V1, EtherCAT, Modbus/TCP, EtherNet/IP, CANopen, DeviceNet, POWERLINK, CC-Link.
  • Galvanic isolation: 500 V DC between the current paths.
  • Interface: u-remote system bus.
  • Module type: Functional module.
  • Output current: 0.5 A.
  • Transmission speed of system bus, maximum: 48 Mbit.