Back to Top
UR20-1COM-232-485-422
Remote I/O module, IP20, 1-channel, communication protocols RS232/RS485/RS422, PUSH IN connection:
- In today's automated systems, incremental and absolute value encoders are essential components.
- Weidmüller provides you with a variety of counter modules that can take input frequencies up to 500 kHz. These counter modules were created specifically for these applications.
- The synchronous serial interface (SSI) module allows high precision positioning tasks to be realized with absolute value encoders.
- To accommodate all applications, the module can be parameterized for listening or master mode operation.
- A pulse input module is available for frequency measurement up to 100 kHz, while the UR20-1CNT-500 has an input that can handle frequencies up to 500 kHz.
- The UR20-2CNT-100 module has two independent counter inputs; it is supplemented with the UR20-1CNT-100-1DO module, which has one counter but provides additional options via a latch, gate, and reset input.
- THIS PERMITS EXTERNAL COUNTER CONTROL.
- In addition, this module can trigger an immediate event via a digital output using a predefined reference value.
- The UR20-1COM-232-485-422 MODULE GIVES YOU EXTENDED OPTIONS FOR COMMUNICATION; DEVICES CAN BE CONSISTENTLY INTEGRATED IN U-REMOTE SYSTEMS VIA AN RS232, RS485 OR RS422 INTERFACE, FOR EXAMPLE.
- The UR20-1COM-SAI PRO MODULE PROVIDES A SOLUTION FOR CONNECTING THE CONTROL CABINET TO THE FIELD.
- UP TO 15 DECENTRAL IP67 SAI-PRO SUBBUS MODULES PER U-REMOTE MODULE CAN BE INTEGRATED USING THIS GATEWAY.
- THE MODULE ELECTRONICS SUPPLY CONNECTED SENSORS With POWER TO THE INPUT current path (UIN)
Specifications dimensions and weights:
- Depth: 76 mm.
- Depth (inches): 2.992 inch.
- Height: 120 mm.
- Height (inches): 4.724 inch.
- Width: 11.5 mm.
- Width (inches): 0.453 inch.
- Mounting dimension - height: 128 mm.
- Net weight: 87.03 g.
Temperatures:
- Storage temperature: -40 °C - +85 °C.
- Operating temperature: -20 °C - +60 °C.
Environmental Product Compliance:
- REACH SVHC: Lead 7439-92-1.
- SCIP: 82327f13-cd27-455a-ab5b-a62e1996dcf8.
Connection data:
- Type of connection: PUSH IN.
- Wire connection cross section, finely stranded, maximum: 1.5 mm².
- Wire connection cross section, finely stranded, minimum: 0.14 mm².
- Wire cross-section, finely stranded, maximum (AWG): AWG 16.
- Wire cross-section, finely stranded, minimum (AWG): AWG 26.
- Wire cross-section, solid, maximum: 1.5 mm².
- Wire cross-section, solid, maximum (AWG): AWG 16.
- Wire cross-section, solid, minimum: 0.14 mm².
- Wire cross-section, solid, minimum (AWG): AWG 26.
General data:
- Air humidity (operation): 10% to 95%, non-condensing as per DIN EN 61131-2.
- Air humidity (storage): 10% to 95%, non-condensing as per DIN EN 61131-2.
- Air humidity (transport): 10% to 95%, non-condensing as per DIN EN 61131-2.
- Air pressure (operation): ≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2.
- Air pressure (storage): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2.
- Air pressure (transport): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2.
- Pollution severity: 2.
- Rail: TS 35.
- Shock: 15 g over 11 ms, half sinus wave, acc.to IEC 60068-2-27.
- Surge voltage category: II.
- Test voltage: 500 V.
- UL 94 flammability rating: V-0.
- Vibration resistance: 5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6.
IP67 interface:
- Output current, supply voltage: maximum 500 mA.
Power supply:
- Current consumption from IIN (the respective power segment): 16 mA + load.
- Current consumption from Isys, typ.: 8 mA.
- Voltage supply: 24 V DC +20 %/ -15 % via the system bus.
RS interface:
- Output current, supply voltage: maximum 500 mA.
- Standards RS232: DIN 66020, DIN 66259, EIA-RS 232C, CCITT V.24/V.28.
- Standards RS485/422: DIN 66259 Part 1 und 3, EIA-RS 422/485, CCITT V.11.
System data:
- Field bus protocol: PROFINET IRT, PROFINET RT, CC-Link IE TSN, IEC 61162-450, PROFIBUS DP-V1, EtherCAT, Modbus/TCP, EtherNet/IP, CANopen, DeviceNet, POWERLINK, CC-Link.
- Galvanic isolation: 500 V DC between the current paths.
- Interface: u-remote system bus.
- Module type: Functional module.
- Output current: 0.5 A.
- Transmission speed of system bus, maximum: 48 Mbit.
Brand | Weidmuller |
---|
Write Your Own Review