UR20-4DI-P-TS

ZAR 2,859.19
Out of stock
SKU
1460150000

UR20-8DI-P-3W:

  • Weidmüller offers a variety of variants of its digital input modules, which are mostly used to receive binary control signals from switches, proximity switches, transmitters, and sensors.
  • They will meet your need for well-coordinated project planning with reserve potential because of its adaptable design.
  • All modules are available in 4, 8, or 16 input configurations and completely conform with IEC 61131-2.
  • The digital input modules are available in P- or N-switching configurations.
  • The digital inputs are for Type 1 and Type 3 sensors as per the specification.
  • These devices have a maximum input frequency of 1 kHz and can be utilized for a variety of applications.
  • The PLC interface unit variation uses system cables to quickly connect to the well-known Weidmüller interface sub-assemblies.
  • This provides a quick integration into your overall system.
  • Two modules with a timestamp function can collect binary signals and provide a resolution of 1μs.
  • The UR20-4DI-2W-230V-AC module, which accepts a currant up to 230V as an input signal, opens other solutions.
  • The module electronics draw energy from the input current path (UIN) to power the associated sensors.

Specifications dimensions and weights:

  • Depth: 76 mm.
  • Depth (inches): 2.992 inch.
  • Height: 120 mm.
  • Height (inches): 4.724 inch.
  • Width: 11.5 mm.
  • Width (inches): 0.453 inch.
  • Mounting dimension - height: 128 mm.
  • Net weight: 87g.

Temperatures:

  • Storage temperature: -40 °C - +85 °C.
  • Operating temperature: -20 °C - +60 °C.

Environmental Product Compliance:

  • REACH SVHC: Lead 7439-92-1.
  • SCIP: 82327f13-cd27-455a-ab5b-a62e1996dcf8.

digital inputs:

  • Hysteresis: >1 V.
  • Individual channel diagnosis: No.
  • Input filter: configurable.
  • Input voltage, high: > 11 V.
  • Input voltage, low: <5 V.
  • Module diagnosis: Yes.
  • Number of digital inputs: 4.
  • Reverse polarity protection: Yes.
  • Sensor connection: 2-wire, 3-wire, 3-wire + FE
  • Sensor supply: Yes.
  • Sensor supply:
    • minimum: 0 mA.
    • nominal: 750 mA.
    • maximum: 8,000 mA.
  • Time stamp data width: 16 Bit.
  • Time stamp resolution: 1 µs.
  • Type: Types 1 and 3, EN 61131-2.

Connection data:

  • Wire connection cross section, finely stranded, maximum: 1.5 mm².
  • Wire connection cross section, finely stranded, minimum: 0.14 mm².
  • Wire cross-section, finely stranded, maximum (AWG): AWG 16.
  • Wire cross-section, finely stranded, minimum (AWG): AWG 26.
  • Wire cross-section, solid, maximum: 1.5 mm².
  • Wire cross-section, solid, maximum (AWG): AWG 16.
  • Wire cross-section, solid, minimum: 0.14 mm².
  • Wire cross-section, solid, minimum (AWG): AWG 26.

General data:

  • Air humidity (operation): 10% to 95%, non-condensing as per DIN EN 61131-2.
  • Air humidity (storage): 10% to 95%, non-condensing as per DIN EN 61131-2.
  • Air humidity (transport): 10% to 95%, non-condensing as per DIN EN 61131-2.
  • Air pressure (operation): ≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2.
  • Air pressure (storage): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2.
  • Air pressure (transport): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2.
  • Pollution severity: 2.
  • Rail: TS 35.
  • Shock: 15 g over 11 ms, half sinus wave, acc.to IEC 60068-2-27.
  • Surge voltage category: II.
  • Test voltage: 500 V.
  • UL 94 flammability rating: V-0.
  • Vibration resistance: 5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6.

Power supply:

  • Current consumption from IIN (the respective power segment): 10 mA + sensor feed.
  • Current consumption from Isys, typ.: 8 mA.
  • Reverse polarity protection: Yes.
  • Voltage supply: 24 V DC +20 %/ -15 % via the system bus.

System data:

  • Field bus protocol: PROFINET IRT, PROFINET RT, CC-Link IE TSN, IEC 61162-450, PROFIBUS DP-V1, EtherCAT, Modbus/TCP, EtherNet/IP, CANopen, DeviceNet, POWERLINK, CC-Link.
  • Galvanic isolation: 500 V DC between the current paths.
  • Interface: u-remote system bus.
  • Module type: Digital input module.
  • Possible connection: 2-wire, 3-wire, 3 conductor FES, Single-conductor.
  • Transmission speed of system bus, maximum: 48 Mbit.
More Information
Brand Weidmuller
Write Your Own Review
You're reviewing:UR20-4DI-P-TS
Write your content here...