UR20-PF-O-1DI-SIL

ZAR 0.00 ZAR 0.00
Out of stock
SKU
1335030000

Pricing available on request

UR20-PF-O-1DI-SIL:

  • When it comes to industrial automation and machine building, safety technology is crucial.
  • Reducing risks and avoiding hazards for people and the environment requires solutions that meet strict regulations and legal criteria.
  • The u-remote system's safety modules include critical features such as emergency stop circuits and wire breakage or short-circuit detection.
  • They meet all SIL 3 standards as defined by IEC 62061 and EN ISO 13849-1, category 4, PL e, and ensure the safe functioning of your system.

Dimensions and weights:

  • Depth: 76 mm.
  • Depth (inches): 2.992 inch.
  • Height: 120 mm.
  • Height (inches): 4.724 inch.
  • Width: 11.5 mm.
  • Width (inches): 0.453 inch.
  • Mounting dimension - height: 128 mm.
  • Net weight: 108 g.

Temperatures:

  • Storage temperature: -40 °C... +85 °C.
  • Operating temperature: -20 °C... +60 °C.

Environmental Product Compliance:

  • REACH SVHC: Lead 7439-92-1.
  • SCIP: 82327f13-cd27-455a-ab5b-a62e1996dcf8.
  • RoHS Compliance Status: Compliant with exemption.
  • RoHS Exemption (if applicable/known): 7a, 7cI.

digital inputs:

  • Short-circuit detection: Yes.
  • Wire break detection: Yes.

Connection data:

  • Type of connection: PUSH IN.
  • Wire connection cross section, finely stranded, max.: 1.5 mm².
  • Wire connection cross section, finely stranded, min.: 0.14 mm².
  • Wire cross-section, finely stranded, max. (AWG): AWG 16.
  • Wire cross-section, finely stranded, min. (AWG): AWG 26.
  • Wire cross-section, solid, max.: 1.5 mm².
  • Wire cross-section, solid, max. (AWG): AWG 16.
  • Wire cross-section, solid, min.: 0.14 mm².
  • Wire cross-section, solid, min. (AWG): AWG 26.

General data:

  • Air humidity (operation): 10% to 95%, non-condensing as per DIN EN 61131-2.
  • Air humidity (storage): 10% to 95%, non-condensing as per DIN EN 61131-2.
  • Air humidity (transport): 10% to 95%, non-condensing as per DIN EN 61131-2.
  • Air pressure (operation): ≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2.
  • Air pressure (storage): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2.
  • Air pressure (transport): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2.
  • Pollution severity: 2.
  • Rail: TS 35.
  • Shock: 15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27.
  • Surge voltage category: II.
  • Test voltage: 500 V.
  • UL 94 flammability rating: V-0.
  • Vibration resistance: 5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6.

Power supply:

  • Current consumption from IIN (the respective power segment): 35 mA.
  • Current consumption from Isys, typ.: 8 mA.
  • Feed current for IOUT (output current path):
    • min.: 8,050 mA.
    • nominal: 8,050 mA.
    • max.: 8,050 mA.
  • Feed current for IOUT (output current path), max.: 8,050 mA.
  • Supply voltage for outputs: 24 V DC +20 %/ -15 %.
  • Supply voltage system and inputs: 24 V DC +20 %/ -15 %.
  • Voltage supply: 24 V DC +20 %/ -15 %, via the system bus.

Safety characteristics in acc. with EN 61508:

  • HFT (hardware fault tolerance), inputs: 1.
  • Proportion of safety-related outages (SFF): 98 %.

Safety characteristics in acc. with EN ISO 13849:

  • MTTF: 100 a.

System data:

  • Field bus protocol:
    • PROFINET IRT.
    • PROFINET RT.
    • CC-Link IE TSN.
    • IEC 61162-450.
    • PROFIBUS DP-V1.
    • EtherCAT.
    • Modbus/TCP.
    • EtherNet/IP.
    • CANopen.
    • DeviceNet.
    • POWERLINK.
    • CC-Link.
  • Galvanic isolation: 500 V DC between the current paths.
  • Interface: u-remote system bus.
  • Module type: Safe power-feed module.
  • Transmission speed of system bus, max.: 48 Mbit.