Motortronics Synergy Soft Starter, 3-Phase, 52A
Motortronics Synergy Soft Starter:
- Synergy™ is changing the rule book on motor controller size and performance.
- It achieves a 54% reduction in controller size in comparison to rival products.
Motor overload protection:
- Protecting the motor and soft starter in the event of an overload condition at full I²t motor overload with an intelligent thermal memory retention feature.
- Monitoring overloads continuously to determine the decrease in motor temperature even when VMX-synergyTM is turned "off."
- This, paired with protection and diagnostics, gives the operator peace of mind when running the motor.
Specifications:
- The range is 17–477A, or 10-400 horsepower.
- 3-phase SCR.
- Memory provides full motor overload.
- Standard Trip Class 10: 3 x 23 or 3.5 x 17 seconds.
- 3 or 5 starts each hour (Trip Classes 20 and 30 are customizable).
- Volts: 208, 230, 400, and 480.
- Operates at frequencies ranging from 45 Hz to 65 Hz.
- Bypassed internally.
- NEMA 1, IP00, and IP20.
- A full-colour touch screen is easy to use.
- Fully automatic set-up.
- Control voltages: 110/230 VAC and 24 VDC.
- Energy Recovery System (iERS) as a standard feature.
- In a delta or 6-wire connection.
- Multiple languages.
- Modbus RTU is standard, with other protocols available as an option.
- Input/Output:
- 4 x programmable output relays.
- 3 programmable digital inputs.
- Input and output in analogue.
- USB for data logging and parameter setting and saving.
- Thermistor.
- Comprehensive data logging.
- Fully field-upgradable through a USB port.
- Fans are fully field-serviceable.
- 2-year warranty.
- 52 Amps.
- Trip class 10 AC-53a; 3,5-17: 90-5; 3-23: 90-5.
- Trip class 20 AC-53a; 4-19: 90-5.
- Trip class 30 AC-53a; 4-29: 90-5.
- Dimensions (mm): 270 x 95.2 x 177.1.
- Weight: 3.5 kg.
Event logging:
- The VMX-synergy™ data logger records all events, allowing for fast, reliable fault analysis and resolution.
- Recording various activities such as start, stop, top of ramp, faults, application parameters (time, overload level, currents, frequency), and device information.
- Event logs can be obtained by using a USB port or VMX-synergy™ commissioning software.
Soft stopping:
- Water hammers can be eliminated with Soft Stop Control.
- When you activate the stop signal, your pump motor's output torque gradually decreases.
- Check valves are now softly shut, and other parts of the fluid system are spared the force and potentially catastrophic effects of a water hammer.
Brand | Motortronics |
---|
Write Your Own Review
Write your content here...