Welcome

Enter your email to continue.

AI Assistant
Cart
    View Cart
    Quote
      Add to Quote

      Fieldbus slave CX2500-B310

      SKU: CX2500-B310

      Out of stock

      Availability: Out of Stock

      Short Description
      Fieldbus: PROFIBUS DP, DP-V1 Data transfer rates: 9.6 kbaud…12 Mbaud Bus interface: 1 x D-sub socket, 9-pin Bus device: max. 125 slaves Interface to the CPU: PCI Express Max. number of bytes: max. 244 byte input/244 byte output Max. power loss: 2.8 W Dimensions (W x H x D): 24 mm x 99 mm x 54.5 mm Weight: approx. 180 g Operating/storage temperature: -25…+60 °C/-40…+85 °C Relative humidity: 95 %, no condensation Vibration/shock resistance: conforms to EN 60068-2-6/EN 60068-2-27 EMC immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4 Protection rating: IP20
      CX2500-B310
      Alternative image 1
      The CX2500-Bxxx fieldbus slave modules are left-sided attachments for the Embedded PC series CX20xx and CX52x0. The use of systems with fieldbus slave modules enables the use of a CX system as a subordinate local controller for the construction of complex or modular systems. External process data are received from the master and processed, or data from its own process peripherals are returned to the master controller directly or processed. The CX2500-B310 fieldbus slave module assumes the function of a PROFIBUS slave. Each module occupies a PCI Express lane, so that a total of four of these modules can be connected in any desired combination to the left side of a CX20xx group. The fieldbus slave modules are single-channel modules. The CX2500-B310 fieldbus slave module for PROFIBUS can present itself to the master as a multiple (max. quadruple) virtual slave station, resulting in a four-fold increase in the quantity of exchanged process data. The parallel operation of several identical or different slaves is possible, e.g. two PROFIBUS slaves or a PROFIBUS slave and a CANopen slave. In the case of mixed operation of master and slave connections, CX systems act as intelligent gateways between different fieldbuses: data are received, processed and fed into other fieldbuses. Master or slave connections network several CX systems with one another strictly deterministically via the fieldbus level. CX fieldbus modules can be retrofitted/exchanged by adding them to existing CX systems. The scanning and recognizing of the modules, the parameterization, the configuration of the connected I/O components and the online diagnostics of the process/fieldbus status take place in the TwinCAT System Manager.

      Associated Products